Estimation of flow rate through analysis of pipe vibration
Document Type
Article
Publication Title
Acta Mechanica et Automatica
Abstract
In this paper, implementation of soft sensing technique for measurement of fluid flow rate is reported. The objective of the paper is to design an estimator to physically measure the flow in pipe by analysing the vibration on the walls of the pipe. Commonly used head type flow meter causes obstruction to the flow and measurement would depend on the placement of these sensors. In the proposed technique vibration sensor is bonded on the pipe of liquid flow. It is observed that vibration in the pipe varies with the control action of stem. Single axis accelerometer is used to acquire vibration signal from pipe, signal is passed from the sensor to the system for processing. Basic techniques like filtering, amplification, and Fourier transform are used to process the signal. The obtained transform is trained using neural network algorithm to estimate the fluid flow rate. Artificial neural network is designed using back propagation with artificial bee colony algorithm. Designed estimator after being incorporated in practical setup is subjected to test and the result obtained shows successful estimation of flow rate with the root mean square percentage error of 0.667.
First Page
294
Last Page
300
DOI
10.2478/ama-2018-0045
Publication Date
12-1-2018
Recommended Citation
K. V, Santhosh and Navada, Bhagya R., "Estimation of flow rate through analysis of pipe vibration" (2018). Open Access archive. 11.
https://impressions.manipal.edu/open-access-archive/11