This study aims to propose building envelope retrofit packages for existing naturally ventilated school buildings in the hot–humid climatic region of Chennai, India. Indoor thermal parameters were collected through field studies from nine sample classrooms of a selected school building in May 2019, between 9.00 am and 4.00 pm. The thermal performance assessment of the existing building was performed by examining the discomfort hours using the CBE thermal comfort tool. Envelope retrofit strategies gathered from the literature and building standards were applied and studied through simulation. The findings reveal the enormous potential to increase the thermal comfort of existing school buildings through envelope retrofit measures. The results demonstrate that the whole-building temperature can be reduced up to 3.2 °C in summer and up to 3.4 °C in winter. Implementing retrofit measures to the building envelopes of existing buildings will help school owners to increase the comfortable hours of whole buildings by up to 17%. In comparison, annual energy savings of up to 13% for the whole building can be made by enhancing the thermal performance of the building envelope. The findings will also help architects to optimise thermal performance and energy usage with minimal interventions.